Evaluation of Fire Protection System in Library Building Universitas Negeri Padang
DOI:
https://doi.org/10.24036/cived.v11i2.494Keywords:
Fire-alarm, Protection-system, Library-buildingAbstract
The fire of a building will have a major impact on the building owner, both in the form of material, moral and environmental losses. In residential areas, offices and other public facilities often cause casualties. Therefore, a building needs to take into account the risk of fire so that building users can carry out activities safely and comfortably. One of the causes of fires is the fire suppression system that has not received full attention, where there is often an inadequate building fire protection system. The UNP Library Building is one of the public facilities buildings that are always crowded with students. It is necessary to evaluate the availability of the fire protection system to ensure the safety and comfort of its users. This research is in the form of an evaluation of the availability and completeness of the available fire protection systems and their remedies against the threat of fire. The data was taken through direct observation and question and answer and the distribution of questionnaires with the library. From the results of the analysis of the fire protection system inspection of the UNP Library building, it is known that on the 1st floor the lowest rediness value is 18.9%, for the 2nd and 3rd floors is 44.1%, the 4th and 5th floors are 45.9% and 45.6 % fulfilled the requirements based on the Minister of Public Works Regulation No. 26/PRT/M/2008.
Downloads
References
Undang-Undang Republik Indonesia Nomor 28 Tahun 2002 tentang Bangunan Gedung
Keputusan Menteri Negera Pekerjaan Umum Nomor: 10/KPTS/2000 tentang KetentuanTeknis Pengamanan terhadap Bahaya Kebakaran pada Bangunan Gedung dan Lingkungan
Peraturan Menteri Pekerjaan Umum Nomor: 05/PRT/M/2014 tentang Pedoman Sistem Manajemen Keselamatan dan Kesehatan Kerja (SMK3) Konstruksi Pekerjaan Umum
Peraturan Menteri Pekerjaan Umum Nomor: 26/PRT/M/2008 tentang Persyaratan Teknis Sistem Proteksi Kebakaran pada Bangunan Gedung dan Lingkungan
SNI03-1736-2000 tentang Tata Cara Perencanaan Sistem Produksi Pasif untuk Pencegahan Bahaya Kebakaran pada Bangunan Rumah dan Gedung
Peraturan Pemerintah Republik Indonesia Nomor: 36 Tahun 2005 tentang Peraturan Pelaksanaan UU Nomor 28 Tahun 2002 tentang Bangunan Gedung
Sama’mur. 1997. Keselamatan Kerja dan Pencegahan Kecelakaan. Jakarta: CV Haji Musagung
SNI03-1735-2000 tentang Tata Cara Perencanaan Akses Bangunan dan Akses Lingkungan untuk Pencegahan Bahaya Kebakaran pada Bangunan Gedung
SNI03-2989-2000 tentang Tata Cara Perencanaan dan Pemasangan Sistem Sprinkler Otomatik untuk Pencegahan Bahaya Kebakaran pada Bangunan Gedung
Karimah Minanti, Kurniawan, 2016. “Analisis Upaya Penanggulangan Kebakaran Di Gedung Bougenville Rumah Sakit Telogorejo Semarang”, Jurnal Kesehatan Masyarakat, Volume 4 No 4 tahun 2016. http://ejournal-s1.undip.ac.id/index.php/jkm
Sulaeman Agus, Widjasena B., Ekawati. “Analisis Sistem Proteksi Kebakaran Pada Suatu Rumah Sakit” Jurnal Ilmiah Permas: Jurnal Ilmiah STIKES Kendal, Volume 12 Nomor 2, April 2022. http://journal.stikeskendal.ac.id/index.php/PSKM
Cornellia, Gatherine.2019. Tinjauan Kelaikan Fasilitas Kesehatan di Kota Padang terhadap Keamanan akibat Kebakaran. Proyek Akhir. Padang: UNP
Dwi Hamdayeti, Lauren.2019. Tinjauan Keamanan terhadap Kebakaran pada Puskesmas di Kota Padang, Area Studi: Kecamatan Kuranji, Nanggalo, Padang Timur, Lubuk Begalung, Lubuk Kilangan, Padang Barat (Berdasarkan PERMEN PUPR RI No. 11/PRT/M/2018). Proyek Akhir. Padang: UNP
Nurhaliza Ttiti (2021). Evaluasi Penerapan Sistem Proteksi Kebakaran Aktif di Rumah Sakit Ernaldi Bahar Provinsi Sumatera Selatan, Skripsi, FKM. Universitas Sriwijaya
Khairiyah Helda, “Manajemen Kebakaran Gedung di Kota Pekanbaru”. Jurnal Pendidikan Tambusai, Volume 6 Nomor 1 Tahun 2022, Halaman 3706-3714.
Sujatmiko Wahyu, “The Application of the Standard of Fire Safety Evacuation In Building in Indonesia”. Jurnal Permukiman Vol. 11 No. 2 November 2016: 116-127.
Peterson, Carl E, Steven F. Sawyer, eds. 1998. NFPA 1 Fire Prevention Code Handbook First edition. MA: NFPA.
Peraturan Menteri Pekerjaan Umum Nomor: 25/PRT/M/2007 tentang Pedoman Sertifikat Laik Fungsi Bangunan Gedung
Sujatmiko, W. 2016. Pengembangan Kriteria Desain Pasif yang Memenuhi Kenyamanan Termal dan Keselamatan Kebakaran pada Bangunan Rumah Susun Sederhana Bertingkat Tinggi. Disertasi. Bandung: ITB.
SFPE. 2007. SFPE Engineering Guide to Performance-Based Fire Protection, 2nd edition, MA: NFPA
Ramli, Soehatman. 2010. Pedoman Praktis Manajemen Bencana (Disaster Management). Dian Rakyat.
Kuligowski, E., Peacock, R., Wiess, E., & Hoskins, B. 2013. Stair evacuation of older adults and people with mobility impairments. Fire Safety Journal, 62: 230–237